onsdag 3 december 2014

In this project

In this project we have not been able to evaluate exactly how these allocations have been made. For some of the studied installation sites a part (up to 20%) of the total electricity consumption has been allocated neither to space heating nor to the domestic hot water production. This is mainly the case for the electricity consumption. For the heat produced no energy gap is seen between the total energy production and the energy divided into space heating and domestic hot water.  
The calculated SPF’s in the study are based on the energy allocated to the space heating only, this in order to make the results comparable to the results from the calculation models in prEN14825 and Lot 1, which not include the production of domestic hot water.
Air to air heat pumps The field measurement of the air to air heat pumps is carried out in single family houses located in the Borås area of Sweden. All houses in the study have electricity driven radiators for back up heating.  The field measurements are based on SP method 1721. From the field measurements SPF2 and SPF3 has been calculated as described below.

Inga kommentarer:

Skicka en kommentar